Large Diameter DALK part 1

Large Diameter DALK 9.5mm bed / 9.75mm donor laterality matched (Left eye donor to Left eye recipient) donor nasal marked for better registration once transplanted-designed to reduce suture-out astigmatism, big bubble dissection descemets membrane (DM) extends to 8.0mm diameter. Since host partial thickness trephination is 9.5mm diameter, manual radial dissection of DM must be done from 8.0mm to 9.5mm for 360 degrees using small, blunt tipped dissector to carefully break adhesions. No perforations occurred. (unedited)